One sash, two movements: secure night ventilation plus a full inward opening for cleaning.
Request a QuoteAll ProductsThe GH-UP110 is the dual-operation workhorse of the GLOBHAUS uPVC range. A single handle rotates through three positions: locked, tilted inwards about 10–15 degrees for controlled background ventilation, and fully swung inward for maximum opening and safe cleaning of the outer glass from inside the building.
The inward swing is the reason this configuration dominates Central and Northern European apartment specifications, and why it suits high-rise projects where outward sashes are prohibited or where external access is expensive. Multi-chamber lead-free PVC-U profiles are reinforced with galvanised steel, and the whole perimeter is carried by a single multi-point locking circuit rather than isolated corner locks.
It is specified most often for apartments, hotels, schools and hospitals, where a facilities team needs a window that ventilates without a security risk and can be cleaned without scaffolding.
| Profile system | 70 / 80 / 88 mm multi-chamber lead-free PVC-U with galvanised steel reinforcement |
|---|---|
| Operation | Tilt (approx. 10–15°) + inward turn, single handle, three positions |
| Hardware | Multi-point perimeter locking, mushroom cams, adjustable hinge/friction stay, optional tilt limiter |
| Glazing | 24–44 mm IGU: double Low-E, triple, laminated acoustic or tempered safety glass |
| Sealing | Dual or triple compression gasket system with corner-welded seals |
| Thermal / acoustic target | Uw and Rw targets set by glazing and profile series; declared values supplied per project calculation |
| Finish | White, black, grey, bronze, wood-grain film or custom RAL-matched laminate |
| Certification | NFRC / PHI / CSA documentation can be prepared for the destination market; confirm the exact standard and test report required at RFQ stage. |
| Sizes | Made to the structural opening; max sash size confirmed against wind load at RFQ stage |
| Warranty / MOQ / Lead time | 10 years on profile · 1 × 20 ft container · 30–40 days |
| Service | OEM / ODM, project engineering, container-loaded export packing |
These are the points that decide whether the unit performs as specified after handover. They are issued as a drawing package with the order and should be read alongside the project’s own structural and waterproofing details.
Record width, height, diagonal and reveal depth on every opening; uPVC is made to measure and on-site trimming of a welded frame is not a workable correction.
Fix a levelled sub-frame or use packers at all fixing points. A twisted frame is the single most common cause of a tilt-turn sash that will not lock.
Mechanical fixings through the frame or bracket, typically 400–600 mm apart and within 150 mm of corners; keep fixings clear of drainage channels and the steel reinforcement.
Apply exterior vapour-open / interior vapour-tight tapes or a compatible sealant system, and keep the frame drainage path open to daylight.
Set glazing blocks at the correct diagonal positions, then adjust the hinge, stay and striker plates through the full tilt and turn cycle before silicone cures.
Demonstrate handle positions, issue the hardware adjustment sheet and record the project-specific spare-part list for the facilities team.
Inward operation removes the need for external access and satisfies façade rules that prohibit outward-opening sashes.
Tilt position delivers ventilation while the restricted opening keeps the room secure and limits noise ingress.
Controlled background ventilation without a wide-open sash, plus easy internal cleaning for facilities staff.
Triple glazing and deeper profile series give the thermal performance needed for heating-dominated projects.
Wipe profiles with a mild detergent and soft cloth; avoid solvent cleaners that attack the surface film. Vacuum drainage slots and weep holes twice a year, lubricate the locking cams and hinge points annually with a light hardware grease, and re-check striker adjustment if the handle stiffens. Gaskets are replaceable without dismantling the sash, which is why the tilt-turn platform is economical over a 20–30 year service life.
| Criterion | This configuration | Alternative |
|---|---|---|
| Ventilation while locked | Tilt position with multi-point engagement still active | Casement: either closed or fully open |
| External access for cleaning | Not required — sash swings inward | Outward casement: usually required above ground floor |
| Hardware complexity / cost | Higher — one handle drives a full perimeter gearbox | Lower — simpler hinge and stay set |
| Best fit | Apartments, hotels, high-rise, cold climates | Low-rise housing, mild climates, budget-led programmes |
A single-sash window whose handle selects three positions: locked, tilted inward roughly 10–15 degrees for ventilation, or fully swung inward. It gives secure background ventilation and lets the outer glass be cleaned from inside the room.
Yes — the inward swing is often preferred on upper floors because no sash projects over the façade and cleaning needs no external access. Sash size and hardware grade are confirmed against the project wind load at RFQ stage.
The 24–44 mm glazing rebate accepts double Low-E, triple, laminated acoustic and tempered safety IGUs. Target Uw and Rw values are calculated from the chosen build-up rather than quoted as a fixed number.
Minimum order is one 20 ft container and production lead time is normally 30–40 days after drawing approval. Mixed configurations can be loaded in the same container.
Yes. The hinge, gearbox and cam geometry follow standard tilt-turn dimensions, and a project-specific spare-part list is supplied at handover so distributors can stock wear items.
Send the opening schedule, glazing build-up and target market. Quotations within 24 hours.
Request a QuoteSend your opening schedule and glass build-up — we return a quote and full export documentation.
Originally published on globhaus.com · 2026-11-06